The dell/ folder holds four templates for three Dell switch families, all Core and Pro. This page covers release v2.2.2. The folder has no README; what follows comes from the template files and their header comments.
Which template
| Template | Use for |
|---|---|
dell-ftos-ssh-enable |
Force10 FTOS (Dell Networking OS9) over SSH, with enable |
dell-networking-ssh-noenable |
Dell Networking switches over SSH, account already privileged |
dell-powerconnect-telnet-enable |
PowerConnect over telnet, with enable |
dell-powerconnect-telnet-noenable |
PowerConnect over telnet, without enable |
FTOS and the command line ending
FTOS ignores a command that ends in a bare carriage return, which is what rConfig sends after login unless told otherwise. The FTOS template sets commandLinebreak: "n" so commands go out with a newline instead.
That key needs rConfig Pro V8.4.0 or Core 8.2.19 or later. Older versions ignore it without an error, and the symptom is distinctive: login and enable succeed, then every show command times out or comes back empty. Login itself is unaffected, because the login steps always send a newline.
The templates
rConfig-templates / dell /dell-ftos-ssh-enable.ymlView on GitHub- Protocol
- SSH, port 22
- Enable
- on
- Line ending
- commandLinebreak: n
- Status
- untested-starter
- Protocol
- SSH, port 22
- Enable
- off
- Paging
- terminal length 0
- Status
- community-tested
- Protocol
- Telnet, port 23
- Enable
- on
- Paging
- terminal length 0
- Status
- community-tested
- Protocol
- Telnet, port 23
- Enable
- off
- Paging
- terminal datadump
- Status
- community-tested